Benchmark MPA1 Manuale delle Istruzioni Pagina 24

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 30
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 23
MPA1 Instruction Manual Page 24
LED Output Meters and Gain Indicators
Output Meters 4-LED Meter (per channel)
Output Level Indicators +28 dBu (red)
+24 dBu (orange)
+4 dBu (green)
-20 dBu (green)
Gain Indicators Max 74 dB” RED LED: Total Gain =
+74 dB (Maximum preamp gain)
+48 dB” GREEN LED: Total Gain =
Dial + 48 dB
+24 dB” GREEN LED: Total Gain =
Dial + 24 dB
NO LED: Total Gain = Dial + 0 dB
Min 0dB” RED LED: Total Gain =
Unity Gain (Minimum preamp gain)
AC Power Requirements
Input Operating Voltage Range (VAC RMS) 120 V setting: 105 V min, 140 V max
220 V setting : 200 V min, 285 V max
Frequency 50-60 Hz
Power 27 Watts Idle
27 Watts Typical Program
35 Watts Maximum
Fuses 5 x 20 mm (2 required)
0.5 A 250 V Slo-Bl
Littelfuse® HXP218.500 or Equivalent
Vedere la pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 30

Commenti su questo manuale

Nessun commento